非磁性换热管现场电磁(涡流)检验的标准实施规程  
 【英文标准名称】  Standard Practice for In Situ Electromagnetic (Eddy-Current) Examination of Nonmagnetic Heat Exchanger Tubes
 【原文标准名称】  非磁性换热管现场电磁(涡流)检验的标准实施规程
 【标准号】  ASTM E690-2010
 【标准状态】  Active
 【国别】  美国
 【发布日期】  2010
 【实施或试行日期】  
 【发布单位】  美国材料与试验协会(US-ASTM)
 【起草单位】  E07.07
 【标准类型】  (Practice)
 【标准水平】  ()
 【中文主题词】  
 【英文主题词】  eddy-current; electromagnetic; NDT; nondestructive testing; Condenser and heat exchanger systems; Curie temperature; Eddy current examination; Electromagnetic (eddy current) testing; Nonmagnetic heat exchanger tubes
 【摘要】  

Eddy-current examination is a nondestructive method of locating discontinuities in tubing made of materials that conduct electricity. Signals can be produced by discontinuities located either on the inner or outer surfaces of the tube, or by discontinuities totally contained within the tube wall. When using an internal probe, the density of eddy currents in the tube wall decreases very rapidly as the distance from the internal surface increases; thus the amplitude of the response to outer surface discontinuities decreases correspondingly.

Some indications obtained by this method may not be relevant to product quality. For example, an irrelevant signal may be caused by metallurgical or mechanical variations that are generated during manufacture but that are not detrimental to the end use of the product. Irrelevant indications can mask unacceptable discontinuities occurring in the same area. Relevant indications are those that result from nonacceptable discontinuities. Any indication above the reject level, which is believed to be irrelevant, shall be regarded as unacceptable until it is proven to be irrelevant. For tubing installed in heat exchangers, predictable sources of irrelevant indications are lands (short unfinned sections in finned tubing), dents, scratches, tool chatter marks, or variations in cold work. Rolling tubes into the supports may also cause irrelevant indications, as may the tube supports themselves. Eddy-current examination systems are generally not able to separate the indication generated by the end of the tube from indications of discontinuities adjacent to the ends of the tube (end effect). Therefore, this examination may not be valid at the boundaries of the tube sheets.

1.1 This practice describes procedures to be followed during eddy-current examination (using an internal, probe-type, coil assembly) of nonmagnetic tubing that has been installed in a heat exchanger. The procedure recognizes both the unique problems of implementing an eddy-current examination of installed tubing, and the indigenous forms of tube-wall deterioration which may occur during this type of service. The document primarily addresses scheduled maintenance inspection of heat exchangers, but can also be used by manufacturers of heat exchangers, either to examine the condition of the tubes after installation, or to establish baseline data for evaluating subsequent performance of the product after exposure to various environmental conditions. The ultimate purpose is the detection and evaluation of particular types of tube integrity degradation which could result in in-service tube failures.

1.2 This practice does not establish acceptance criteria; they must be specified by the using parties.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 【中国标准分类号】  H26
 【国际标准分类号】  
 【页数】  4P.;A4
 【正文语种】  英语
索取全文
标准全文由山东省标准化研究院向您提供(不能使用知网账号下载全文),需向山东省标准化研究院支付相关费用后,方可获得标准。

 

       

标准间关联  
本领域专利与科技成果  
本标准研制背景
本标准应用动态
所涉核心技术研究动态
京ICP证040431号 互联网出版许可证 新出网证(京)字008号 京公网安备11010802014875号
© 2014中国知网(CNKI) 《中国学术期刊(光盘版)》电子杂志社有限公司
服务热线:400-810-9888 订卡热线:800-810-6613
在线咨询:http://help.cnki.net 客服中心:http://service.cnki.net 电子邮件:help@cnki.net